View Categories

Battery Management: Discharge & Voltage Curves

Understanding your voltage levels is essential for maintaining “peak efficiency” throughout a one-hour race. Since you only have a limited energy budget, monitoring your battery’s state of charge ensures you don’t run out of power before the final lap.

1. Voltage Benchmarks #

For a standard 24V Lead-Acid system (two 12V batteries in series), use these benchmarks to gauge your “energy potential”:

  • Static (No Load): A fully charged system should read over 26 Volts when the car is stationary.
  • Nominal (Under Load): Once the race begins and the motor is drawing current, the voltage will typically drop to roughly 24 Volts.
  • Operating Range: Expect a steady, predictable decline from 24 Volts down to 21 Volts.

2. The “Cliff”: Low Voltage Risks #

Dropping below 21 Volts is a critical warning sign for two reasons:

  • Power Loss: You will experience a rapid loss of torque and top-end speed, often referred to as “falling off the curve.”
  • Battery Damage: Discharging batteries below this threshold can cause permanent chemical damage, reducing their lifespan and capacity for future races.

Comparison: Gearing & Energy Consumption #

How you “alter your gearing to meet needs” directly impacts your battery voltage.

ScenarioImpact on VoltageResult
Geared Too High Sharp, rapid voltage drops during starts or inclines.Potential for early battery depletion and “rapid power loss.”
Optimal GearingSteady, gradual decline over the full 60 minutes.Reaches ~21V just as you cross the finish line.
Geared Too Low Voltage stays high throughout the race.You finish the race with “tons of energy left over” and a slower average speed.

Pro Tip: If your vehicle “rumbles or shakes” over potholes, itโ€™s not just a mechanical issueโ€”itโ€™s “robbing your vehicle of precious energy” that could otherwise keep your voltage stable for longer.

Scroll to Top